5925000077461

CIRCUIT BREAKER

Part No.: 70-132-12MG6,711570-23,APL1-19-23R,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925000077461 CIRCUIT BREAKER 07/12/1972 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
70-132-12MG6 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
711570-23 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL1-19-23R ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
TEST DATA DOCUMENT 05869-711570 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
FREQUENCY IN HERTZ 60.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
THREAD QUANTITY PER INCH 32
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 115.0 AC AND 50.0 DC
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF
FRAGILITY FACTOR MODERATELY RUGGED
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
ACTUATOR FUNCTION TRIP-RESET
BOSS HEIGHT 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.775 INCHES MINIMUM AND 2.955 INCHES MAXIMUM
SPECIAL HANDLING FEATURE MAGNETIC
RESET METHOD MANUAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC AND 50.0 DC SINGLE LOCATION
NOMINAL THREAD SIZE 0.138 INCHES
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
UNPACKAGED UNIT WEIGHT 0.312 POUNDS NOMINAL
CASE MATERIAL PLASTIC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
SWITCH TERMINAL TYPE TAB, SOLDER LUG
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC AND 2000.0 DC SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ACTUATOR POSITION DESIGNATION AT POLE ONE
SWITCH CURRENT RATING AND TYPE IN AMPS 5.0 AC AND 1.0 DC
ARC QUENCHING METHOD MAGNETIC BLOWOUT
TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
POLE QUANTITY 1
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
THREAD PITCH DIAMETERS +0.1177 TO 0.1214 INCHES
BODY LENGTH 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
BODY STYLE SINGLE POLE TYPE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZJ01 05/01/2022
ZW01 12/01/1995

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 04/01/1975 Active