5925000163758

CIRCUIT BREAKER

Part No.: G383729,G383729,G383729,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925000163758 CIRCUIT BREAKER 01/01/1961 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
G383729 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
G383729 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
G383729 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SECOND LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 DC FIRST LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.600 NOMINAL AT 200 PCT SECOND LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC FIRST LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
THREAD QUANTITY PER INCH 32
POLE QUANTITY 3
CASE MATERIAL PLASTIC
ACTUATOR FUNCTION TRIP-RESET
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
ACTUATOR POSITION DESIGNATION AT EACH POLE
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
NOMINAL THREAD SIZE 0.138 INCHES
BOSS HEIGHT 0.130 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.500 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 700.0 MILLIAMPERES DC FIRST LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS FIRST LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
RESET METHOD MANUAL
BODY WIDTH 2.280 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC THIRD LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SECOND LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.600 NOMINAL AT 200 PCT THIRD LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC THIRD LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC SECOND LOCATION
FREQUENCY IN HERTZ 60.0 THIRD LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
FREQUENCY IN HERTZ 60.0 SECOND LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY THIRD LOCATION
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
THREAD SERIES DESIGNATOR UNC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC THIRD LOCATION
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY LENGTH 2.530 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZW01 11/01/2005

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
X P 69F0 3G 1 AAA 0.8 lbs 0.028 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 FA BG X D1 DO 00 E Q U

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 01/16/1981 Active