5925000501297
CIRCUIT BREAKER
Part No.:
MP164800260,CK150-46D,CK150-46D,S1596-60,
NSN Summary
NSN |
Description |
Assign |
Criticality |
Status |
Codification Country |
5925000501297 |
CIRCUIT BREAKER |
05/09/1967 |
X |
Pending Cancellation
|
|
Open Solicitations
Issued |
Closing |
Solicitation |
Clin |
Cage |
ECV |
Status |
Request A Demo
Request a Demo to see all details.
Manufacturers
Part Number |
Company |
Cage |
P/N added |
P/N deleted |
RNVC |
RNCC |
RNAAC |
RNFC |
SADC |
DAC |
Item Status |
MP164800260 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
CK150-46D |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
CK150-46D |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
S1596-60 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
Request A Demo
Request a Demo to see all details.
Procurement History
Company |
Cage |
Award Date |
Qty |
Unit Price |
Total Price |
Contract |
Delivery |
Request A Demo
Request a Demo to see all details.
Management Data
MOE |
SOS |
AAC |
Unit Pack |
UOM |
Unit Price |
SLC |
Date ELA |
FCS |
MCC |
Technical Info
Name |
Value |
BODY STYLE |
SINGLE POLE TYPE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
125.0 AC SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCKPROOF AND VIBRATIONPROOF |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
POLE QUANTITY |
1 |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH BUTTON |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
60.0 AMPERES AC SINGLE LOCATION |
NOMINAL THREAD SIZE |
0.469 INCHES |
CASE MATERIAL |
PLASTIC |
THREAD QUANTITY PER INCH |
32 |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
138.0 SINGLE LOCATION |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
RESET METHOD |
MANUAL |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.718 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.844 INCHES NOMINAL |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
ACTUATOR FUNCTION |
RESET |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
7.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC SINGLE LOCATION |
THREAD SERIES DESIGNATOR |
UNS |
BUSHING LENGTH |
0.297 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
BODY WIDTH |
0.562 INCHES MAXIMUM |
BODY LENGTH |
1.375 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG Inc Info
FIIG |
INC |
Description |
Detail |
00136 |
00136 |
CIRCUIT BREAKER |
|
MOE Data
Country |
MOE |
AMC |
AMSC |
NIMSC |
Eff Date |
IMC |
IMCA |
DSOR |
Collaborator |
Receiver |
AAC |
FMOE |
|
ZW01 |
|
|
|
12/01/1995 |
|
|
|
|
|
|
|
|
YD01 |
|
|
|
08/01/2016 |
|
|
|
|
|
|
|
Freight Data
Integrity |
Originating |
HMC |
WCC |
TCC |
SHC |
ADC |
ACC |
ASH |
LTL |
NMFC |
NMFC Sub Item |
UFC |
Freight Description |
Rail Variance |
|
TX |
|
72D |
Z |
9 |
A |
H |
Z |
W |
063160 |
Z |
35205 |
SWITCH BOXES/ELEC ENCLOSURES |
|
Packaging Data
Source |
PICA / SICA |
Packaging Category |
Storage |
Preservation |
Clean/Dry |
INT Qty |
Unit Weight |
Unit Size |
Unit Pack Cube |
Item Weight |
Item Dims |
P |
P |
69F0 |
|
41 |
1 |
AAA |
0.1 lbs |
|
0.001 cu ft |
|
|
Preservation Material |
Wrapping Material |
Cushioning / Dunnage |
Cushioning Thickness |
Unit Container |
Intermediate Container |
UCL |
Special Marking |
Level A Packing |
Level B Packing |
Minimal Packing |
Optional Procedure |
00 |
FA |
00 |
0 |
XX |
D1 |
|
00 |
Q |
Q |
|
O |
Item Standardization
Status Code |
Originator |
Date |
Status |
Authorized for Procurement |
TX |
10/21/1967 |
Pending Cancellation |