5925000525874
CIRCUIT BREAKER
Part No.:
4565474-2,AM12MG6-10-120VAC60C5,4565474-2,4MC2-105-10,124-210-101,
NSN Summary
NSN |
Description |
Assign |
Criticality |
Status |
Codification Country |
5925000525874 |
CIRCUIT BREAKER |
01/01/1961 |
X |
Active
|
|
Open Solicitations
Issued |
Closing |
Solicitation |
Clin |
Cage |
ECV |
Status |
Request A Demo
Request a Demo to see all details.
Manufacturers
Part Number |
Company |
Cage |
P/N added |
P/N deleted |
RNVC |
RNCC |
RNAAC |
RNFC |
SADC |
DAC |
Item Status |
4565474-2 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
AM12MG6-10-120VAC60C5 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
4565474-2 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
4MC2-105-10 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
124-210-101 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
Request A Demo
Request a Demo to see all details.
Procurement History
Company |
Cage |
Award Date |
Qty |
Unit Price |
Total Price |
Contract |
Delivery |
Request A Demo
Request a Demo to see all details.
Management Data
MOE |
SOS |
AAC |
Unit Pack |
UOM |
Unit Price |
SLC |
Date ELA |
FCS |
MCC |
Technical Info
Name |
Value |
THREAD SERIES DESIGNATOR |
UNC |
BODY STYLE |
SINGLE POLE TYPE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CASE MATERIAL |
PLASTIC |
BOSS HEIGHT |
0.140 INCHES NOMINAL |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.500 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.611 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.938 INCHES NOMINAL |
ACTUATOR FUNCTION |
TRIP-RESET |
FRAGILITY FACTOR |
MODERATELY RUGGED |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC SINGLE LOCATION |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
THREAD QUANTITY PER INCH |
32 |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
10.0 AMPERES AC SINGLE LOCATION |
NOMINAL THREAD SIZE |
0.138 INCHES |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF AND FUNGUS PROOF |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC SINGLE LOCATION |
RESET METHOD |
MANUAL |
POLE QUANTITY |
1 |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
SPECIAL HANDLING FEATURE |
MAGNETIC |
TERMINAL TYPE AND QUANTITY |
2 THREADED STUD |
BODY WIDTH |
0.750 INCHES NOMINAL |
FREQUENCY IN HERTZ |
60.0 SINGLE LOCATION |
BODY LENGTH |
2.500 INCHES NOMINAL |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG Inc Info
FIIG |
INC |
Description |
Detail |
00136 |
00136 |
CIRCUIT BREAKER |
|
MOE Data
Country |
MOE |
AMC |
AMSC |
NIMSC |
Eff Date |
IMC |
IMCA |
DSOR |
Collaborator |
Receiver |
AAC |
FMOE |
|
ZU01 |
|
|
|
04/01/1991 |
|
|
|
|
|
|
|
|
YB01 |
|
|
|
07/01/2003 |
|
|
|
|
|
|
|
Freight Data
Integrity |
Originating |
HMC |
WCC |
TCC |
SHC |
ADC |
ACC |
ASH |
LTL |
NMFC |
NMFC Sub Item |
UFC |
Freight Description |
Rail Variance |
|
XX |
|
658 |
Z |
9 |
A |
H |
Z |
M |
061360 |
X |
34430 |
COILS/YOKES FOCUS/DEFLECTION TV |
|
Packaging Data
Source |
PICA / SICA |
Packaging Category |
Storage |
Preservation |
Clean/Dry |
INT Qty |
Unit Weight |
Unit Size |
Unit Pack Cube |
Item Weight |
Item Dims |
|
|
|
|
|
|
|
|
|
|
|
|
Preservation Material |
Wrapping Material |
Cushioning / Dunnage |
Cushioning Thickness |
Unit Container |
Intermediate Container |
UCL |
Special Marking |
Level A Packing |
Level B Packing |
Minimal Packing |
Optional Procedure |
|
|
|
|
|
|
|
|
|
|
|
|
Item Standardization
Status Code |
Originator |
Date |
Status |
Authorized - Replacement |
TX |
07/06/2022 |
Active |