5925000540402

CIRCUIT BREAKER

Part No.: SM333HHK7-5-240VAC400C1,128C099H08,AP112-12HRR,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925000540402 CIRCUIT BREAKER 05/25/1967 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
SM333HHK7-5-240VAC400C1 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
128C099H08 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AP112-12HRR ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC
DLA SMS J 1 EA 357.66 0 10/01/2024

A PHP Error was encountered

Severity: Notice

Message: Undefined index: frase_code_statement

Filename: open_search/nsn_details.php

Line Number: 248

Backtrace:

File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
Line: 248
Function: _error_handler

File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
Line: 558
Function: view

File: /var/www/www.fbobiz.com/public_html/catalog/index.php
Line: 317
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Undefined index: frase_code_statement

Filename: open_search/nsn_details.php

Line Number: 256

Backtrace:

File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
Line: 256
Function: _error_handler

File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
Line: 558
Function: view

File: /var/www/www.fbobiz.com/public_html/catalog/index.php
Line: 317
Function: require_once

Air Force SMS J 1 EA 357.66 0 10/01/2024

A PHP Error was encountered

Severity: Notice

Message: Undefined index: frase_code_statement

Filename: open_search/nsn_details.php

Line Number: 248

Backtrace:

File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
Line: 248
Function: _error_handler

File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
Line: 558
Function: view

File: /var/www/www.fbobiz.com/public_html/catalog/index.php
Line: 317
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Undefined index: frase_code_statement

Filename: open_search/nsn_details.php

Line Number: 256

Backtrace:

File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
Line: 256
Function: _error_handler

File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
Line: 558
Function: view

File: /var/www/www.fbobiz.com/public_html/catalog/index.php
Line: 317
Function: require_once

Technical Info

Name Value
BUSHING LENGTH 0.375 INCHES NOMINAL
SWITCH CURRENT RATING AND TYPE IN AMPS 1.0 AC AND 0.5 DC
NOMINAL THREAD SIZE 0.375 INCHES
ACTUATOR FUNCTION TRIP-RESET
FRAGILITY FACTOR MODERATELY RUGGED
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
AUXILIARY SWITCH FUNCTION AND QUANTITY 2 CONTROL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
THREAD QUANTITY PER INCH 32
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
POLE QUANTITY 3
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.875 INCHES NOMINAL
SPECIAL HANDLING FEATURE MAGNETIC
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 150 PCT AND 15.000 MAXIMUM AT 150 PCT ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 7.5 AMPERES AC ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 3 THREADED BUSHING
SWITCH TERMINAL TYPE TAB, SOLDER LUG
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT POLE TWO
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
RESET METHOD MANUAL
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.678 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNEF
ULTIMATE TRIP TIME PER POLE IN SECONDS 6.5000 MINIMUM AND 30.000 MAXIMUM ALL LOCATIONS
TEST DATA DOCUMENT 97942-128C099 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 125.0 AC AND 50.0 DC
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
ARC QUENCHING METHOD MAGNETIC BLOWOUT
THREAD PITCH DIAMETERS +0.3503 TO 0.3537 INCHES
BODY WIDTH 1.872 INCHES NOMINAL
BODY LENGTH 1.495 INCHES NOMINAL
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
FXGX 1 L 04/01/2006 Z SX FXTX

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 72D Z 9 A H Z W 063160 Z 35205 SWITCH BOXES/ELEC ENCLOSURES

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69F0 41 1 AAA 0.4 lbs 0.017 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 FA BG C D1 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 10/21/1967 Active