5925000613338

CIRCUIT BREAKER

Part No.: M39019-2-50,MILC39019-2,352250008476,260-4061-400,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925000613338 CIRCUIT BREAKER 06/20/1967 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
M39019-2-50 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
MILC39019-2 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
352250008476 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
260-4061-400 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
BODY STYLE SINGLE POLE TYPE
BUSHING LENGTH 0.280 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
ULTIMATE TRIP TIME PER POLE IN SECONDS 3.000 MINIMUM AND 60.000 MAXIMUM SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.700 INCHES MAXIMUM
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
ACTUATOR FUNCTION TRIP-RESET
SWITCH TERMINAL TYPE TAB, SOLDER LUG
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC SINGLE LOCATION
SWITCH CURRENT RATING AND TYPE IN AMPS 0.5 AC AND 0.5 DC
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC SINGLE LOCATION
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 120.0 AC AND 50.0 DC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
TERMINAL TYPE AND QUANTITY 2 WIRE HOOK
ACTUATOR POSITION DESIGNATION AT POLE ONE
POLE QUANTITY 1
THREAD QUANTITY PER INCH 32
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT AND 1.750 MAXIMUM AT 400 PCT SINGLE LOCATION
FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
TEST DATA DOCUMENT 81349-MIL-C-29019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THREAD SERIES DESIGNATOR UNEF
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
RESET METHOD MANUAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
NOMINAL THREAD SIZE 0.375 INCHES
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC SINGLE LOCATION
BODY LENGTH 1.562 INCHES MAXIMUM
BODY WIDTH 0.625 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZW01 11/01/1998
ZG01 01/01/2015
YD01 08/01/2016
ZU01 07/01/2005

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 01/01/1977 Active