5925000719844

CIRCUIT BREAKER

Part No.: AM0666MG6-25-208VAC60C4,AM0666MG6SW50-250VRC25-208V60C4,CB5461R,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925000719844 CIRCUIT BREAKER 07/25/1967 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
AM0666MG6-25-208VAC60C4 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM0666MG6SW50-250VRC25-208V60C4 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
CB5461R ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC
DLA SMS J 1 EA 55.14 0 10/01/2022

A PHP Error was encountered

Severity: Notice

Message: Undefined index: frase_code_statement

Filename: open_search/nsn_details.php

Line Number: 248

Backtrace:

File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
Line: 248
Function: _error_handler

File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
Line: 558
Function: view

File: /var/www/www.fbobiz.com/public_html/catalog/index.php
Line: 317
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Undefined index: frase_code_statement

Filename: open_search/nsn_details.php

Line Number: 256

Backtrace:

File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
Line: 256
Function: _error_handler

File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
Line: 558
Function: view

File: /var/www/www.fbobiz.com/public_html/catalog/index.php
Line: 317
Function: require_once

Technical Info

Name Value
INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP FOURTH LOCATION
BODY WIDTH 2.960 INCHES MINIMUM AND 3.040 INCHES MAXIMUM
INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC FOURTH LOCATION
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
THREAD QUANTITY PER INCH 32
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SECOND LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC THIRD LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 FOURTH LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC FOURTH LOCATION
NOMINAL THREAD SIZE 0.138 INCHES
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CASE MATERIAL PLASTIC
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC FIRST LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SECOND LOCATION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 8 THREADED HOLE
INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP SECOND LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
MANUAL ACTUATOR TYPE AND QUANTITY 4 TOGGLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC FIRST LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SECOND LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
ACTUATOR FUNCTION TRIP-RESET
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SECOND LOCATION
UNPACKAGED UNIT WEIGHT 13.000 OUNCES NOMINAL
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ACTUATOR POSITION DESIGNATION AT EACH POLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
RESET METHOD MANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT SECOND LOCATION
SPECIAL FEATURES POLE ONE IS SWITCH ONLY
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
POLE QUANTITY 4
FRAGILITY FACTOR MODERATELY RUGGED
TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, AND FOUR LINKED
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.539 INCHES MINIMUM AND 2.683 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 208.0 AC SECOND LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT FOURTH LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY THIRD LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC THIRD LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT THIRD LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY FOURTH LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 208.0 AC THIRD LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC SECOND LOCATION
TERMINAL TYPE AND QUANTITY 8 THREADED STUD
THREAD SERIES DESIGNATOR UNC
CIRCUIT PROTECTION TYPE OVERCURRENT FOURTH LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 208.0 AC FOURTH LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC FOURTH LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 THIRD LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC THIRD LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT THIRD LOCATION
BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
DGX1 0 0 04/01/2006 TX DTX1

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 72D Z 9 A H Z W 063160 Z 35205 SWITCH BOXES/ELEC ENCLOSURES

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69Z0 41 1 AAA 1.1 lbs
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA C D3 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/21/1969 Active