5925000781957

CIRCUIT BREAKER

Part No.: SM33-10-250VAC60HZ2,MIL-C-39019/3,M39019/03-57,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925000781957 CIRCUIT BREAKER 08/11/1967 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
SM33-10-250VAC60HZ2 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
MIL-C-39019/3 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
M39019/03-57 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
BODY LENGTH 1.562 INCHES MAXIMUM
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ULTIMATE TRIP TIME PER POLE IN SECONDS 0.200 MINIMUM AND 7.000 MAXIMUM ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
FRAGILITY FACTOR MODERATELY RUGGED
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HERMETICALLY SEALED AND MOISTURE RESISTANT
UNPACKAGED UNIT WEIGHT 3.400 OUNCES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
TEST DATA DOCUMENT 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
ACTUATOR FUNCTION TRIP-RESET
TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
ACTUATOR POSITION DESIGNATION AT EACH POLE
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
POLE QUANTITY 2
PRECIOUS MATERIAL SILVER
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
SPECIAL HANDLING FEATURE MAGNETIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
SPECIFICATION/STANDARD DATA 81349-MIL-C-39019-3 GOVERNMENT SPECIFICATION
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
RESET METHOD MANUAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
NOMINAL THREAD SIZE 0.375 INCHES
THREAD SERIES DESIGNATOR UNEF
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
THREAD QUANTITY PER INCH 32
PRECIOUS MATERIAL AND LOCATION CONTACT SURFACES SILVER
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.100 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BODY WIDTH 1.281 INCHES MAXIMUM
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
BUSHING LENGTH 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZW01 11/01/1998

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 72D Z 9 A H Z W 063160 Z 35205 SWITCH BOXES/ELEC ENCLOSURES

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69F0 41 1 AAA 0.4 lbs 0.017 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA X D3 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 12/21/1976 Active