NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925000782841 | CIRCUIT BREAKER | 08/05/1967 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
MP704H | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
105-215-101 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
MP704H | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
369A4590-3 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
369A4590-3 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
POLE QUANTITY | 1 |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 28.0 DC SINGLE LOCATION |
THREAD QUANTITY PER INCH | 32 |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
FRAGILITY FACTOR | MODERATELY RUGGED |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.840 INCHES MAXIMUM |
TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
THREAD SERIES DESIGNATOR | UNS |
RESET METHOD | MANUAL |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 7.5 AMPERES AC AND 7.5 AMPERES DC SINGLE LOCATION |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC AND 6000.0 DC SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.673 INCHES MINIMUM AND 0.735 INCHES MAXIMUM |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ACTUATOR FUNCTION | TRIP-RESET |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND CORROSION RESISTANT AND EXPLOSION RESISTANT AND FUNGUS RESISTANT AND DUSTPROOF AND MOISTURE RESISTANT AND SAND RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
NOMINAL THREAD SIZE | 0.469 INCHES |
BODY STYLE | SINGLE POLE TYPE |
BODY WIDTH | 0.750 INCHES MAXIMUM |
BODY LENGTH | 1.094 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 12/01/2007 | |||||||||||
ZH01 | 04/01/1991 | |||||||||||
ZG01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CT | FF | 658 | Z | 5 | A | H | Y | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 10/08/1965 | Active |