NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925000782842 | CIRCUIT BREAKER | 08/05/1967 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
MP703H | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
105-210-101 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
369A4590-7 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
MS25244-10 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
369A4590-7 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY WIDTH | 0.750 INCHES MAXIMUM |
BODY LENGTH | 1.094 INCHES MAXIMUM |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.693 INCHES MINIMUM AND 0.713 INCHES MAXIMUM |
TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 28.0 DC SINGLE LOCATION |
THREAD QUANTITY PER INCH | 32 |
FRAGILITY FACTOR | MODERATELY RUGGED |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
ARC QUENCHING METHOD | AIR |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.812 INCHES MAXIMUM |
ACTUATOR FUNCTION | TRIP-RESET |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 10.0 AMPERES DC SINGLE LOCATION |
POLE QUANTITY | 1 |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC AND 3500.0 DC SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
NOMINAL THREAD SIZE | 0.469 INCHES |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
UNPACKAGED UNIT WEIGHT | 0.094 POUNDS NOMINAL |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | EXPLOSION RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
RESET METHOD | MANUAL |
FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
CASE MATERIAL | PLASTIC |
THREAD SERIES DESIGNATOR | UNS |
BUSHING LENGTH | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
BODY STYLE | SINGLE POLE TYPE |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
YA01 | 01/01/2017 | |||||||||||
WG01 | 10/01/2017 | |||||||||||
ZF01 | 04/01/1991 | |||||||||||
ZW01 | 11/01/2005 | |||||||||||
ZG01 | 04/01/2014 | |||||||||||
YJ01 | 04/01/1991 | |||||||||||
YB01 | 04/01/1991 | |||||||||||
ZH01 | 04/01/1991 | |||||||||||
VJ01 | 02/01/2019 | |||||||||||
YC01 | 05/01/2021 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CT | 658 | Z | 5 | A | H | Y | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 03/31/1975 | Active |