5925001035095

CIRCUIT BREAKER

Part No.: 555260-036,M39019/03-79,MIL-C-39019/3,SM33-20-240-400-2,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925001035095 CIRCUIT BREAKER 06/17/1968 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
555260-036 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
M39019/03-79 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
MIL-C-39019/3 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
SM33-20-240-400-2 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
BUSHING LENGTH 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
THREAD QUANTITY PER INCH 32
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC ALL LOCATIONS
FRAGILITY FACTOR MODERATELY RUGGED
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
SPECIAL HANDLING FEATURE MAGNETIC
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
NOMINAL THREAD SIZE 0.375 INCHES
POLE QUANTITY 2
ARC QUENCHING METHOD MAGNETIC BLOWOUT
RESET METHOD MANUAL
THREAD SERIES DESIGNATOR UNEF
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
SPECIFICATION/STANDARD DATA 81349-MIL-C-39019/3 GOVERNMENT SPECIFICATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HERMETICALLY SEALED
TEST DATA DOCUMENT 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
BODY LENGTH 1.562 INCHES MAXIMUM
BODY WIDTH 1.281 INCHES MAXIMUM
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZC01 04/01/1991
YD01 08/01/2016

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 03/21/1977 Active