NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925001123029 | CIRCUIT BREAKER | 08/23/1968 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
AM12HKMG6-3-250VAC60C4 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
AM12HKMG6-3-250-4-60 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
BODY STYLE | SINGLE POLE TYPE |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 CONTROL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CASE MATERIAL | PLASTIC |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
RESET METHOD | MANUAL |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
ACTUATOR FUNCTION | TRIP-RESET |
SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC |
UNPACKAGED UNIT WEIGHT | 4.250 OUNCES NOMINAL |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES AC SINGLE LOCATION |
SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
NOMINAL THREAD SIZE | 0.138 INCHES |
THREAD QUANTITY PER INCH | 32 |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT AND EXPLOSION RESISTANT |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
POLE QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
THREAD SERIES DESIGNATOR | UNC |
BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 04/01/1991 | |||||||||||
ZR01 | 07/01/1997 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | 69F0 | 3G | 1 | AAA | 0.1 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 99 | E | Q | U | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized - Replacement | TX | 12/12/1975 | Active |