5925001488124

NO ITEM NAME AVAILABLE

Part No.: AM4-Z1-3,SM-A-742924-3,APL5111-1REC2-3235-3,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925001488124 NO ITEM NAME AVAILABLE 06/03/1974 X Cancelled

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
AM4-Z1-3 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
SM-A-742924-3 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL5111-1REC2-3235-3 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC
Army SMS Z 1 EA 91.71 0 01/01/2023 Q23TV
DLA SMS Z 1 EA 91.71 0 01/01/2023

Technical Info

Name Value
POLE QUANTITY 4
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 60.0 AMPERES AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TERMINAL TYPE AND QUANTITY 10 THREADED STUD
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY FIRST LOCATION TIME DELAY SECOND LOCATION TIME DELAY THIRD LOCATION INSTANTANEOUS FOURTH LOCATION
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 8 THREADED HOLE
FREQUENCY IN HERTZ 50.0 OR 60.0 OR 400.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIRST LOCATION SERIES TRIP SECOND LOCATION SERIES TRIP THIRD LOCATION RELAY TRIP FOURTH LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY WIDTH 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
THREAD QUANTITY PER INCH 32
THREAD PITCH DIAMETERS 0.1177 TO 0.1214 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY 4 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, AND FOUR LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 125.0 AC
SWITCH TERMINAL TYPE TAB, SOLDER LUG
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND VIBRATION RESISTANT
III ARC QUENCHING METHOD MAGNETIC BLOWOUT
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III FRAGILITY FACTOR MODERATELY RUGGED

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
NO ITEM NAME AVAILABLE

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
A918 1 G 04/01/2006 Z CD CL A196

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
GX

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69Z0 B 41 1 AAA 0.1 lbs 0.001 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA C D3 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Cancelled