5925001537864

CIRCUIT BREAKER

Part No.: AM33HEMG6-5-65VAC60C5,11242043-25,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925001537864 CIRCUIT BREAKER 10/22/1971 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
AM33HEMG6-5-65VAC60C5 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
11242043-25 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
TERMINAL TYPE AND QUANTITY 4 THREADED STUD
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS 1.300 MINIMUM AND 6.000 MAXIMUM ALL LOCATIONS
BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
RESET METHOD MANUAL
ARC QUENCHING METHOD MAGNETIC BLOWOUT
SWITCH CURRENT RATING AND TYPE IN AMPS 2.5 AC AND 1.0 DC
ACTUATOR FUNCTION TRIP-RESET
CASE MATERIAL PLASTIC
THREAD QUANTITY PER INCH 32
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 AC ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.250 MINIMUM AT 200 PCT AND 0.840 MAXIMUM AT 200 PCT ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
NOMINAL THREAD SIZE 0.138 INCHES
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
POLE QUANTITY 2
SWITCH TERMINAL TYPE TAB, SOLDER LUG
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
BODY WIDTH 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
FRAGILITY FACTOR MODERATELY RUGGED
ACTUATOR POSITION DESIGNATION AT EACH POLE
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
THREAD SERIES DESIGNATOR UNC
BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
YB01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
BR 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69F0 41 1 AAA
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA X D3 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/01/1974 Active