5925001670592

CIRCUIT BREAKER

Part No.: APL11R554-070,260-4065-070,AM33HKMG6-0.75-250-15-400,AM33HKMG6-0-75-250VAC400C15,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925001670592 CIRCUIT BREAKER 11/20/1971 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
APL11R554-070 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
260-4065-070 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM33HKMG6-0.75-250-15-400 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM33HKMG6-0-75-250VAC400C15 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
BODY LENGTH 2.500 INCHES NOMINAL
THREAD PITCH DIAMETERS +0.1177 TO 0.1214 INCHES
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
FRAGILITY FACTOR MODERATELY RUGGED
BOSS HEIGHT 0.140 INCHES NOMINAL
UNPACKAGED UNIT WEIGHT 8.750 OUNCES NOMINAL
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
RESET METHOD MANUAL
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.062 INCHES NOMINAL
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 75.0 MILLIAMPERES AC ALL LOCATIONS
SWITCH CURRENT RATING AND TYPE IN AMPS 2.5 AC AND 1.0 DC
SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
SWITCH TERMINAL TYPE TAB, SOLDER LUG
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.938 INCHES NOMINAL
NOMINAL THREAD SIZE 0.138 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
THREAD QUANTITY PER INCH 32
CASE MATERIAL PLASTIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT EACH POLE
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
POLE QUANTITY 2
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
TERMINAL TYPE AND QUANTITY 4 THREADED STUD
THREAD SERIES DESIGNATOR UNC
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.611 INCHES NOMINAL
ACTUATOR FUNCTION TRIP-RESET
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.500 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH 1.500 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZG01 01/01/2015
ZW01 11/01/1998
ZU01 03/01/2008

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 02/10/1980 Active