CIRCUIT BREAKER

Part No.: 5925001731036,APL115-2816-1,72-330-1MG6,AM633MG6-20,10237508,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925001731036 CIRCUIT BREAKER 12/01/1971 X Pending Cancellation

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
5925001731036 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL115-2816-1 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
72-330-1MG6 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM633MG6-20 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
10237508 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC
DLA SMS Z 1 EA 106.43 0 01/01/2023

Technical Info

Name Value
THREAD SERIES DESIGNATOR UNC
BODY LENGTH 2.530 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
SWITCH TERMINAL TYPE THREADED STUD
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS 500.000 NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
THREAD QUANTITY PER INCH 32
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 25.000 MINIMUM AT 200 PCT AND 150.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CASE MATERIAL PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.950 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.540 INCHES NOMINAL
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
NOMINAL THREAD SIZE 0.138 INCHES
SWITCH CURRENT RATING AND TYPE IN AMPS 20.0 AC
BOSS HEIGHT 0.150 INCHES NOMINAL
SWITCH CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY CLOSED
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
ACTUATOR POSITION DESIGNATION AT EACH POLE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1500.0 AC ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.070 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
THREAD PITCH DIAMETERS +0.1177 TO 0.1214 INCHES
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
ACTUATOR FUNCTION RESET
POLE QUANTITY 3
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH 2.280 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
YP01 01/01/2017
YD01 08/01/2016

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 72D Z 9 A H Z W 063160 Z 35205 SWITCH BOXES/ELEC ENCLOSURES

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 60F0 B 10 1 AAA 1 lbs 0.1 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 ZZ C D3 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/01/1974 Pending Cancellation