5925001740387 | CIRCUIT BREAKER | 01/01/1961 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
F3015 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
1222032 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
1222032 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
45-70 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 7.245 INCHES MINIMUM AND 7.255 INCHES MAXIMUM |
TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
POLE QUANTITY | 3 |
UNTHREADED MOUNTING HOLE DIAMETER | 0.276 INCHES MINIMUM AND 0.286 INCHES MAXIMUM |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.369 INCHES MINIMUM AND 1.379 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.495 INCHES MINIMUM AND 4.505 INCHES MAXIMUM |
BOSS HEIGHT | 0.120 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
ACTUATOR POSITION DESIGNATION | AT POLE TWO |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC ALL LOCATIONS |
RESET METHOD | MANUAL |
SPECIAL HANDLING FEATURE | MAGNETIC |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CASE MATERIAL | PLASTIC |
ARC QUENCHING METHOD | DEION |
TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
ACTUATOR FUNCTION | TRIP-RESET |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.369 INCHES MINIMUM AND 1.379 INCHES MAXIMUM |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
BODY WIDTH | 4.120 INCHES MINIMUM AND 4.130 INCHES MAXIMUM |
FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
BODY LENGTH | 9.370 INCHES MINIMUM AND 9.380 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
BODY HEIGHT | 3.807 INCHES MINIMUM AND 3.817 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 03/01/2008 | |||||||||||
ZC01 | 04/01/1991 | |||||||||||
YA01 | 12/01/1999 | |||||||||||
ZW01 | 11/01/1998 | |||||||||||
YB01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX | 72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH BOXES/ELEC ENCLOSURES |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 42 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | FA | JC | X | EC | DO | Q | Q | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 02/14/1982 | Active |