5925002014793

CIRCUIT BREAKER

Part No.: 0142-25DCCURVEUN90,1090142,3363S-25-125VDC-2,3363S-25-125-2-VDC,3363S25DCCURVE2,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925002014793 CIRCUIT BREAKER 01/01/1963 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
0142-25DCCURVEUN90 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
1090142 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
3363S-25-125VDC-2 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
3363S-25-125-2-VDC ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
3363S25DCCURVE2 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
MOUNTING SURFACE TO TERMINAL END DISTANCE 3.302 INCHES MINIMUM AND 3.322 INCHES MAXIMUM
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 125.0 DC ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES DC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
FRAGILITY FACTOR MODERATELY RUGGED
UNTHREADED MOUNTING HOLE DIAMETER 0.190 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
POLE QUANTITY 3
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT POLE TWO
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 DC ALL LOCATIONS
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
BOSS HEIGHT 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
ACTUATOR FUNCTION TRIP-RESET
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
ARC QUENCHING METHOD MAGNETIC BLOWOUT
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
BODY WIDTH 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
RESET METHOD MANUAL
CASE MATERIAL PLASTIC
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
BODY LENGTH 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZU01 04/01/1991
ZW01 11/01/2005
ZH01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69Z0 41 1 AAA
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA X EC DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/03/1969 Active