5925002020740
CIRCUIT BREAKER
Part No.:
MILC7079,AN3161-5,
NSN Summary
NSN |
Description |
Assign |
Criticality |
Status |
Codification Country |
5925002020740 |
CIRCUIT BREAKER |
01/01/1963 |
X |
Active
|
|
Open Solicitations
Issued |
Closing |
Solicitation |
Clin |
Cage |
ECV |
Status |
Request A Demo
Request a Demo to see all details.
Manufacturers
Part Number |
Company |
Cage |
P/N added |
P/N deleted |
RNVC |
RNCC |
RNAAC |
RNFC |
SADC |
DAC |
Item Status |
MILC7079 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
AN3161-5 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
Request A Demo
Request a Demo to see all details.
Procurement History
Company |
Cage |
Award Date |
Qty |
Unit Price |
Total Price |
Contract |
Delivery |
Request A Demo
Request a Demo to see all details.
Management Data
MOE |
SOS |
AAC |
Unit Pack |
UOM |
Unit Price |
SLC |
Date ELA |
FCS |
MCC |
Technical Info
Name |
Value |
RESET METHOD |
AUTOMATIC |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
138.0 SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
10.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 100.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
NOMINAL THREAD SIZE |
0.138 INCHES |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF |
THREAD QUANTITY PER INCH |
32 |
POLE QUANTITY |
1 |
OVERALL LENGTH |
2.188 INCHES NOMINAL |
OVERALL WIDTH |
0.750 INCHES NOMINAL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1500.0 DC SINGLE LOCATION |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
30.0 DC SINGLE LOCATION |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
THREAD SERIES DESIGNATOR |
UNC |
OVERALL HEIGHT |
2.625 INCHES NOMINAL |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES DC SINGLE LOCATION |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG Inc Info
FIIG |
INC |
Description |
Detail |
00136 |
00136 |
CIRCUIT BREAKER |
|
MOE Data
Country |
MOE |
AMC |
AMSC |
NIMSC |
Eff Date |
IMC |
IMCA |
DSOR |
Collaborator |
Receiver |
AAC |
FMOE |
|
ZU01 |
|
|
|
04/01/1991 |
|
|
|
|
|
|
|
Freight Data
Integrity |
Originating |
HMC |
WCC |
TCC |
SHC |
ADC |
ACC |
ASH |
LTL |
NMFC |
NMFC Sub Item |
UFC |
Freight Description |
Rail Variance |
|
XX |
|
658 |
Z |
9 |
A |
H |
Z |
M |
061360 |
X |
34430 |
COILS/YOKES FOCUS/DEFLECTION TV |
|
Packaging Data
Source |
PICA / SICA |
Packaging Category |
Storage |
Preservation |
Clean/Dry |
INT Qty |
Unit Weight |
Unit Size |
Unit Pack Cube |
Item Weight |
Item Dims |
|
|
|
|
|
|
|
|
|
|
|
|
Preservation Material |
Wrapping Material |
Cushioning / Dunnage |
Cushioning Thickness |
Unit Container |
Intermediate Container |
UCL |
Special Marking |
Level A Packing |
Level B Packing |
Minimal Packing |
Optional Procedure |
|
|
|
|
|
|
|
|
|
|
|
|
Item Standardization
Status Code |
Originator |
Date |
Status |
Authorized for Procurement |
TX |
10/08/1965 |
Active |