5925002293519

CIRCUIT BREAKER

Part No.: 150-0865,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925002293519 CIRCUIT BREAKER 02/10/1969 X Inactive

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
150-0865 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
SWITCH TERMINAL TYPE THREADED STUD
RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS 208.0 AC
UNTHREADED MOUNTING HOLE DIAMETER 0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT POLE ONE
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SHUNT TRIP ALL LOCATIONS
AUXILIARY SWITCH FUNCTION AND QUANTITY 12 ALARM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 600.0 AC ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 75.000 MINIMUM AT 100 PCT AND 1000.000 MAXIMUM AT 100 PCT AND 46.000 MINIMUM AT 200 PCT AND 300.000 MAXIMUM AT 200 PCT AND 40.000 MINIMUM AT 300 PCT AND 150.000 MAXIMUM AT 300 PCT AND 34.000 MINIMUM AT 400 PCT AND 90.000 MAXIMUM AT 400 PCT AND 28.000 MINIMUM AT 500 PCT AND 65.000 MAXIMUM AT 500 PCT AND 10.000 MINIMUM AT 1000 PCT AND 18.000 MAXIMUM AT 1000 PCT ALL LOCATIONS
TERMINAL TYPE AND QUANTITY 6 BUS BAR
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 208.0 AC AND 46.0 DC
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
ULTIMATE TRIP TIME PER POLE IN SECONDS 56.000 NOMINAL ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 35000.0 AC ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 600.0 AMPERES AC ALL LOCATIONS
SPECIAL FEATURES LONG DELAY PICKUP,LONG TIME DELAYBAND,INSTANTANEOUS PICKUP SETTINGS ADJUSTABLE.
FEATURES PROVIDED ADJUSTABLE TRIP RELEASE
MANUAL ACTUATOR TYPE AND QUANTITY 1 ROTARY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
POLE QUANTITY 3
SWITCH CURRENT RATING AND TYPE IN AMPS 12.0 AC AND 24.0 DC
RESET METHOD ELECTRIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 3.625 INCHES NOMINAL
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
BODY LENGTH 17.562 INCHES NOMINAL
OVERALL HEIGHT 16.188 INCHES NOMINAL
MOUNTING SLOT WIDTH 0.187 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
ACTUATOR FUNCTION RESET
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 10.562 INCHES NOMINAL
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS +280.0 TO 460.0 AC AND +1750.0 TO 5250.0 AC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 11.625 INCHES NOMINAL
BODY HEIGHT 17.000 INCHES NOMINAL
OVERALL LENGTH 17.000 INCHES NOMINAL
OVERALL WIDTH 12.750 INCHES NOMINAL
BODY WIDTH 12.750 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
HH FF 658 Z 5 A H Y M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
A P ZZZZ B 53 1 000 325 lbs 36in x 36in x 36in 27 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 JA LK 0 F2 00 B 03 Q F M

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/21/1969 Inactive