5925002403424 | CIRCUIT BREAKER | 01/01/1963 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
B40421-1 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
0411CSKMG4-6-5-230AC3 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
PCB832-0411CSKMG4-6-5A230VACC3 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
0411CSMG4-6-5AMP2302CURVE | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
0411CSM6-6-5 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
0411CS | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
0411CSKMG46-5AMP230V | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
THREAD SERIES DESIGNATOR | UNC |
FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
TERMINAL TYPE AND QUANTITY | 1 TAB W/SCREW AND 1 SCREW |
POLE QUANTITY | 1 |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SINGLE LOCATION |
CASE MATERIAL | PLASTIC |
RESET METHOD | MANUAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4.303 INCHES MINIMUM AND 4.323 INCHES MAXIMUM |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.350 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
ACTUATOR FUNCTION | TRIP-RESET |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
FRAGILITY FACTOR | MODERATELY RUGGED |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 230.0 AC SINGLE LOCATION |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 6.5 AMPERES AC SINGLE LOCATION |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
THREAD QUANTITY PER INCH | 32 |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE AND 1 UNTHREADED HOLE |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
NOMINAL THREAD SIZE | 0.138 INCHES |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
BODY WIDTH | 1.015 INCHES MINIMUM AND 1.035 INCHES MAXIMUM |
BODY HEIGHT | 2.600 INCHES MINIMUM AND 2.620 INCHES MAXIMUM |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
UNTHREADED MOUNTING HOLE DIAMETER | 0.164 INCHES NOMINAL |
BODY STYLE | SINGLE POLE TYPE |
BODY LENGTH | 4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 04/01/1991 | |||||||||||
WB01 | 02/01/2005 | |||||||||||
ZW01 | 09/01/2009 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 12/20/1969 | Active |