NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925002509767 | CIRCUIT BREAKER | 06/29/1973 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
APL-111-1RE-42-103-MA | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
99047433 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
99047433 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
99047433 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
BODY WIDTH | 2.250 INCHES MAXIMUM |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
ACTUATOR FUNCTION | TRIP-RESET |
MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.475 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
UNPACKAGED UNIT WEIGHT | 11.100 OUNCES NOMINAL |
RESET METHOD | MANUAL |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 3.0 DC |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
SPECIAL HANDLING FEATURE | MAGNETIC |
NOMINAL THREAD SIZE | 3.0 MILLIMETERS |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.940 INCHES NOMINAL |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
SWITCH TERMINAL TYPE | QUICK DISCONNECT, MALE |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FRAGILITY FACTOR | MODERATELY RUGGED |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
ACTUATOR POSITION DESIGNATION | AT EACH POLE |
BOSS HEIGHT | 0.150 INCHES NOMINAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
THREAD PITCH IN MILLIMETERS | 0.50 |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
POLE QUANTITY | 3 |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
BODY LENGTH | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
THREAD SERIES DESIGNATOR | ISO S |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CASE MATERIAL | PLASTIC |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
YP01 | 05/01/2017 | |||||||||||
WG01 | 10/01/2017 | |||||||||||
ZU01 | 07/01/2005 | |||||||||||
ZF01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
Status Code | Originator | Date | Status |
---|---|---|---|
Not Standardized yet | 98 | 02/01/1975 | Active |