5925002646251

CIRCUIT BREAKER

Part No.: 99067642,99067642,AP11-1RE4-2-502MA,APL11-42-0502REMA,99067642,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925002646251 CIRCUIT BREAKER 07/13/1973 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
99067642 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
99067642 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AP11-1RE4-2-502MA ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL11-42-0502REMA ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
99067642 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
TERMINAL TYPE AND QUANTITY 4 THREADED STUD
THREAD SERIES DESIGNATOR ISO S
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
ARC QUENCHING METHOD MAGNETIC BLOWOUT
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 6.000 MINIMUM AT 150 PCT AND 60.000 MAXIMUM AT 150 PCT AND 0.400 MINIMUM AT 400 PCT AND 1.500 MAXIMUM AT 400 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
UNPACKAGED UNIT WEIGHT 7.400 OUNCES NOMINAL
ULTIMATE TRIP TIME PER POLE IN SECONDS 6.000 MINIMUM AND 60.000 MAXIMUM ALL LOCATIONS
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
NOMINAL THREAD SIZE 3.5 MILLIMETERS
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC
POLE QUANTITY 2
RESET METHOD MANUAL
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
SPECIAL HANDLING FEATURE MAGNETIC
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
SWITCH TERMINAL TYPE TURRET
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 AC ALL LOCATIONS
BOSS HEIGHT 0.150 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.475 INCHES NOMINAL
FRAGILITY FACTOR MODERATELY RUGGED
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
ACTUATOR POSITION DESIGNATION AT EACH POLE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BODY WIDTH 1.530 INCHES MAXIMUM
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY LENGTH 2.490 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
WG01 10/01/2017
ZF01 04/01/1991
ZU01 07/01/2005
ZG01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
ZF 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Not Standardized yet 98 02/01/1975 Active