NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925002791037 | CIRCUIT BREAKER | 01/01/1963 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
AM12MG6-2-28 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
AM12MG6-2-50VDC4 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
555261-060 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
10630082-35 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
918203-442 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES DC SINGLE LOCATION |
ACTUATOR FUNCTION | TRIP W/SEPARATE RESET |
BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
UNPACKAGED UNIT WEIGHT | 0.280 POUNDS NOMINAL |
BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
RESET METHOD | MANUAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.930 INCHES MINIMUM AND 1.950 INCHES MAXIMUM |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
POLE QUANTITY | 1 |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
NOMINAL THREAD SIZE | 0.138 INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC SINGLE LOCATION |
SPECIAL HANDLING FEATURE | MAGNETIC |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
THREAD QUANTITY PER INCH | 32 |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
CASE MATERIAL | PLASTIC |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.408 INCHES MINIMUM AND 2.552 INCHES MAXIMUM |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
BODY LENGTH | 2.500 INCHES MINIMUM AND 2.530 INCHES MAXIMUM |
THREAD SERIES DESIGNATOR | UNC |
PRECIOUS MATERIAL AND LOCATION | TERMINALS SILVER AND NUTS SILVER AND WASHERS SILVER |
PRECIOUS MATERIAL | SILVER |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
BODY STYLE | SINGLE POLE TYPE |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized - Replacement | TX | 04/01/1975 | Active |