5925002792931

CIRCUIT BREAKER

Part No.: PA40,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925002792931 CIRCUIT BREAKER 01/01/1963 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
PA40 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 30.0 AC AND 30.0 DC SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.281 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.574 INCHES NOMINAL
TRIP RELEASE METHOD THERMAL SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 100.000 NOMINAL AT 125 PCT AND 7.500 NOMINAL AT 200 PCT AND 1.900 NOMINAL AT 300 PCT SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 40.0 AMPERES AC AND 40.0 AMPERES DC SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
UNPACKAGED UNIT WEIGHT 1.500 OUNCES NOMINAL
TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
RESET METHOD AUTOMATIC
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 800.0 AC AND 800.0 DC SINGLE LOCATION
FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL
CASE MATERIAL PLASTIC
POLE QUANTITY 1
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 120.0 SINGLE LOCATION
BODY WIDTH 1.188 INCHES NOMINAL
OVERALL LENGTH 2.000 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 2 TAB W/SCREW
BODY STYLE SINGLE POLE TYPE

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZU01 04/01/1991
ZP01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/03/1969 Active