5925003112341

NO ITEM NAME AVAILABLE

Part No.: MIL-PRF-55629/5,APL-111-1-61-402-M,APL-111-55629/5-039,MIL-C-55629/5,M55629/5-039,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925003112341 NO ITEM NAME AVAILABLE 10/26/1973 X Cancelled

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
MIL-PRF-55629/5 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL-111-1-61-402-M ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL-111-55629/5-039 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
MIL-C-55629/5 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
M55629/5-039 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC
DLA SMS Z 1 EA 38.45 0 01/01/2023

Technical Info

Name Value
POLE QUANTITY 3
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 4.0 AMPERES AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
RESET METHOD MANUAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH 2.510 INCHES MAXIMUM
BODY WIDTH 2.205 INCHES MINIMUM AND 2.285 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
BOSS HEIGHT 0.140 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.553 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
THREAD QUANTITY PER INCH 32
THREAD PITCH DIAMETERS 0.1177 TO 0.1214 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
TEST DATA DOCUMENT 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION
III ARC QUENCHING METHOD MAGNETIC BLOWOUT
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III SPECIAL HANDLING FEATURE MAGNETIC
III FRAGILITY FACTOR MODERATELY RUGGED
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-55629/5
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M55629/5-039

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
NO ITEM NAME AVAILABLE

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
DGX1 1 T 04/01/2006 TX DTX1

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
GX

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69FZ B ZZ 1 AAA 0.2 lbs 0.02 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
ZZ ZZ ZZ C ZZ ZZ 00 Q Q O

Item Standardization

Status Code Originator Date Status
Cancelled