NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925003839707 | CIRCUIT BREAKER | 03/21/1974 | X | Pending Cancellation |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
2263SHK-60-115VAC-3 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
351-590-008 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY HEIGHT | 2.688 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
BOSS HEIGHT | 0.219 INCHES NOMINAL |
POLE QUANTITY | 2 |
THREAD QUANTITY PER INCH | 32 |
NOMINAL THREAD SIZE | 0.138 INCHES |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60.0 AMPERES AC AND 60.0 AMPERES DC ALL LOCATIONS |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4.359 INCHES NOMINAL |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE TWO |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC AND 5000.0 DC ALL LOCATIONS |
ACTUATOR FUNCTION | TRIP-RESET |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 250.0 DC ALL LOCATIONS |
RESET METHOD | MANUAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.984 INCHES NOMINAL |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.984 INCHES NOMINAL |
ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CASE MATERIAL | PLASTIC |
ARC QUENCHING METHOD | AIR |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.350 MINIMUM AT 200 PCT AND 3.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
FRAGILITY FACTOR | MODERATELY RUGGED |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.062 INCHES NOMINAL |
SPECIAL HANDLING FEATURE | MAGNETIC |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
BODY LENGTH | 5.250 INCHES NOMINAL |
BODY WIDTH | 2.000 INCHES NOMINAL |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
THREAD SERIES DESIGNATOR | UNC |
FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HD | FF | 658 | Z | 5 | A | H | Y | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | 69FZ | 33 | X | XXX |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
XX | XX | XX | X | XX | XX | 99 | E | Q | U | M |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized - Pending decision | TX | 12/01/1974 | Pending Cancellation |