5925004049035

CIRCUIT BREAKER

Part No.: MIL-C-39019/6,260-4039-760,352250009391,M39019/6-98,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925004049035 CIRCUIT BREAKER 03/31/1971 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
MIL-C-39019/6 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
260-4039-760 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
352250009391 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
M39019/6-98 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE THREE
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
THREAD QUANTITY PER INCH 32
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
SPECIAL HANDLING FEATURE MAGNETIC
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
UNPACKAGED UNIT WEIGHT 150.0 GRAMS NOMINAL
TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED AND MOISTURE RESISTANT AND VIBRATION RESISTANT AND FUNGUS RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
SPECIFICATION/STANDARD DATA 81349-MIL-C-39019/6 GOVERNMENT SPECIFICATION
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
RESET METHOD MANUAL
TEST DATA DOCUMENT 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 6.0 AMPERES AC ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.687 INCHES NOMINAL
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 120.0 AC AND 50.0 DC
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
SWITCH TERMINAL TYPE PIN
ACTUATOR POSITION DESIGNATION AT POLE TWO
POLE QUANTITY 3
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
THREAD SERIES DESIGNATOR UNEF
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
NOMINAL THREAD SIZE 0.375 INCHES
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
SWITCH CURRENT RATING AND TYPE IN AMPS 0.5 AC AND 0.5 DC
FRAGILITY FACTOR MODERATELY RUGGED
BODY LENGTH 1.562 INCHES MAXIMUM
BODY WIDTH 1.937 INCHES MAXIMUM
BUSHING LENGTH 0.332 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
WU01 05/01/2015
ZU01 04/01/1991
ZW01 11/01/1998
ZG01 04/01/1991
YB01 05/01/2004

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 01/18/1977 Active