NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925004071952 | CIRCUIT BREAKER | 07/02/1970 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
870SS0057 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
MS3320-20 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
16100025968 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
MIL-C-5809 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY STYLE | SINGLE POLE TYPE |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
TERMINAL TYPE AND QUANTITY | 2 SCREW |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC SINGLE LOCATION |
NOMINAL THREAD SIZE | 0.438 INCHES |
POLE QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
SPECIFICATION/STANDARD DATA | 96906-MS3320 GOVERNMENT STANDARD |
TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
THREAD QUANTITY PER INCH | 32 |
RESET METHOD | MANUAL |
FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.343 INCHES MAXIMUM |
THREAD SERIES DESIGNATOR | UN |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.500 INCHES NOMINAL |
UNPACKAGED UNIT WEIGHT | 1.200 OUNCES NOMINAL |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BODY WIDTH | 0.593 INCHES MAXIMUM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC SINGLE LOCATION |
ACTUATOR FUNCTION | TRIP-RESET |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
TEST DATA DOCUMENT | 81349-MIL-C-5809 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND EXPLOSION RESISTANT |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 5.000 MINIMUM AT 200 PCT AND 15.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
BUSHING LENGTH | 0.250 INCHES NOMINAL |
BODY LENGTH | 0.781 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
WG01 | 10/01/2017 | |||||||||||
YJ01 | 04/01/1991 | |||||||||||
ZS01 | 07/01/1999 | |||||||||||
ZF01 | 08/01/2002 | |||||||||||
YW01 | 06/01/2018 | |||||||||||
ZC01 | 07/01/2014 | |||||||||||
ZU01 | 04/01/1991 | |||||||||||
YB01 | 04/01/1991 | |||||||||||
VJ01 | 02/01/2019 | |||||||||||
VK01 | 12/01/2018 | |||||||||||
YD01 | 08/01/2016 | |||||||||||
ZH01 | 04/01/1991 | |||||||||||
ZW01 | 11/01/2005 | |||||||||||
ZR01 | 01/01/2003 | |||||||||||
YA01 | 10/01/2001 | |||||||||||
ZG01 | 04/01/1991 | |||||||||||
ZP01 | 04/01/1991 | |||||||||||
ZE01 | 05/01/1994 | |||||||||||
ZN01 | 04/01/1991 | |||||||||||
ZK01 | 04/01/1991 | |||||||||||
YC01 | 07/01/2015 | |||||||||||
WP01 | 11/01/2022 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | 69Z0 | 3G | 1 | AAA | 0.2 lbs | 0.009 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | XX | D3 | 99 | E | Q | U | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 05/11/1986 | Active |