POLE QUANTITY |
2 |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC FIRST LOCATION 20.0 AMPERES DC SECOND LOCATION |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
TERMINAL TYPE AND QUANTITY |
4 QUICK DISCONNECT, MALE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC FIRST LOCATION 65.0 DC SECOND LOCATION |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
RESET METHOD |
MANUAL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CASE MATERIAL |
PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
FREQUENCY IN HERTZ |
50.0 OR 60.0 FIRST LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC FIRST LOCATION 1000.0 DC SECOND LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP FIRST LOCATION RELAY TRIP SECOND LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT AND 11.000 MAXIMUM AT 200 PCT FIRST LOCATION 0.600 MINIMUM AT 200 PCT AND 7.000 MAXIMUM AT 200 PCT SECOND LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
BODY LENGTH |
2.000 INCHES NOMINAL |
BODY WIDTH |
1.500 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.560 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.660 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |
BOSS HEIGHT |
0.130 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.880 INCHES NOMINAL |
THREAD SERIES DESIGNATOR |
UNC |
NOMINAL THREAD SIZE |
0.138 INCHES |
THREAD QUANTITY PER INCH |
32 |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
ACTUATOR FUNCTION |
TRIP-RESET |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF |
III ARC QUENCHING METHOD |
AIR |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
III FRAGILITY FACTOR |
MODERATELY RUGGED |