5925004093617

CIRCUIT BREAKER

Part No.: APL-1-1-62-502,310216,431509,1001817-24,1001817-24,AM12-5-250-60-4,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925004093617 CIRCUIT BREAKER 07/15/1970 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
APL-1-1-62-502 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
310216 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
431509 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
1001817-24 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
1001817-24 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM12-5-250-60-4 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
THREAD PITCH DIAMETERS +0.1177 TO 0.1214 INCHES
TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
ARC QUENCHING METHOD MAGNETIC BLOWOUT
RESET METHOD MANUAL
CASE MATERIAL PLASTIC
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
BOSS HEIGHT 0.150 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
ACTUATOR FUNCTION TRIP-RESET
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
UNPACKAGED UNIT WEIGHT 3.700 OUNCES NOMINAL
POLE QUANTITY 1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC SINGLE LOCATION
NOMINAL THREAD SIZE 0.138 INCHES
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT SINGLE LOCATION
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
ACTUATOR POSITION DESIGNATION AT POLE ONE
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
FRAGILITY FACTOR MODERATELY RUGGED
SPECIAL HANDLING FEATURE MAGNETIC
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 SINGLE LOCATION
FREQUENCY IN HERTZ 50.0 OR 60.0 SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.475 INCHES NOMINAL
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
THREAD QUANTITY PER INCH 32
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
BODY STYLE SINGLE POLE TYPE
THREAD SERIES DESIGNATOR UNC
BODY WIDTH 0.750 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
BODY LENGTH 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZC01 04/01/1991
YD01 08/01/2016
ZG01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
ZG

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P 69F0 3G 1 AAA
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA X D3 DO 99 E Q U O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 09/20/1978 Active