5925004093621
CIRCUIT BREAKER
Part No.:
AM2-A3A20-2,431504,1001817-57,AM33-20-250-60-4,1001817-57,
NSN Summary
NSN |
Description |
Assign |
Criticality |
Status |
Codification Country |
5925004093621 |
CIRCUIT BREAKER |
07/15/1970 |
X |
Active
|
|
Open Solicitations
Issued |
Closing |
Solicitation |
Clin |
Cage |
ECV |
Status |
Request A Demo
Request a Demo to see all details.
Manufacturers
Part Number |
Company |
Cage |
P/N added |
P/N deleted |
RNVC |
RNCC |
RNAAC |
RNFC |
SADC |
DAC |
Item Status |
AM2-A3A20-2 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
431504 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
1001817-57 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
AM33-20-250-60-4 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
1001817-57 |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
######### |
Request A Demo
Request a Demo to see all details.
Procurement History
Company |
Cage |
Award Date |
Qty |
Unit Price |
Total Price |
Contract |
Delivery |
Request A Demo
Request a Demo to see all details.
Management Data
MOE |
SOS |
AAC |
Unit Pack |
UOM |
Unit Price |
SLC |
Date ELA |
FCS |
MCC |
Technical Info
Name |
Value |
TERMINAL TYPE AND QUANTITY |
4 THREADED STUD |
BODY WIDTH |
1.500 INCHES NOMINAL |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC ALL LOCATIONS |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
SPECIAL HANDLING FEATURE |
MAGNETIC |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
CASE MATERIAL |
PLASTIC |
RESET METHOD |
MANUAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
POLE QUANTITY |
2 |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
UNPACKAGED UNIT WEIGHT |
8.750 OUNCES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.471 INCHES NOMINAL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
NOMINAL THREAD SIZE |
0.138 INCHES |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
3.800 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.938 INCHES NOMINAL |
FRAGILITY FACTOR |
MODERATELY RUGGED |
ACTUATOR FUNCTION |
TRIP-RESET |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
BOSS HEIGHT |
0.140 INCHES NOMINAL |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC ALL LOCATIONS |
THREAD QUANTITY PER INCH |
32 |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
THREAD SERIES DESIGNATOR |
UNC |
BODY LENGTH |
2.500 INCHES NOMINAL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG Inc Info
FIIG |
INC |
Description |
Detail |
00136 |
00136 |
CIRCUIT BREAKER |
|
MOE Data
Country |
MOE |
AMC |
AMSC |
NIMSC |
Eff Date |
IMC |
IMCA |
DSOR |
Collaborator |
Receiver |
AAC |
FMOE |
|
ZG01 |
|
|
|
01/01/2015 |
|
|
|
|
|
|
|
|
ZR01 |
|
|
|
07/01/1997 |
|
|
|
|
|
|
|
|
ZW01 |
|
|
|
11/01/2005 |
|
|
|
|
|
|
|
|
ZH01 |
|
|
|
08/01/1995 |
|
|
|
|
|
|
|
Freight Data
Integrity |
Originating |
HMC |
WCC |
TCC |
SHC |
ADC |
ACC |
ASH |
LTL |
NMFC |
NMFC Sub Item |
UFC |
Freight Description |
Rail Variance |
|
ZG |
|
|
|
|
|
|
|
|
|
|
|
|
|
Packaging Data
Source |
PICA / SICA |
Packaging Category |
Storage |
Preservation |
Clean/Dry |
INT Qty |
Unit Weight |
Unit Size |
Unit Pack Cube |
Item Weight |
Item Dims |
|
|
|
|
|
|
|
|
|
|
|
|
Preservation Material |
Wrapping Material |
Cushioning / Dunnage |
Cushioning Thickness |
Unit Container |
Intermediate Container |
UCL |
Special Marking |
Level A Packing |
Level B Packing |
Minimal Packing |
Optional Procedure |
|
|
|
|
|
|
|
|
|
|
|
|
Item Standardization
Status Code |
Originator |
Date |
Status |
Authorized - Replacement |
TX |
12/12/1975 |
Active |