NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925004442589 | CIRCUIT BREAKER | 12/18/1970 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
7234-34-2 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
63213-5 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY LENGTH | 1.874 INCHES NOMINAL |
BUSHING LENGTH | 0.359 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
PRECIOUS MATERIAL | GOLD |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2500.0 AC AND 2500.0 DC SINGLE LOCATION |
NOMINAL THREAD SIZE | 0.469 INCHES |
POLE QUANTITY | 1 |
FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC AND 2.0 AMPERES DC SINGLE LOCATION |
CASE MATERIAL | PLASTIC |
ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 30.0 DC |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 30.0 DC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145.0 SINGLE LOCATION |
UNPACKAGED UNIT WEIGHT | 1.000 OUNCES NOMINAL |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
THREAD QUANTITY PER INCH | 32 |
RESET METHOD | MANUAL |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND EXPLOSION PROOF |
SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
SWITCH CURRENT RATING AND TYPE IN AMPS | 2.0 AC AND 3.0 DC |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.593 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.420 INCHES MAXIMUM |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
BODY WIDTH | 0.750 INCHES NOMINAL |
THREAD SERIES DESIGNATOR | UNS |
BODY STYLE | SINGLE POLE TYPE |
PRECIOUS MATERIAL AND LOCATION | AUXILIARY TERMINALS GOLD |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 04/01/1991 | |||||||||||
YB01 | 04/01/1991 | |||||||||||
ZW01 | 11/01/1998 | |||||||||||
YD01 | 08/01/2016 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HH | 72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH BOXES/ELEC ENCLOSURES |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 69F0 | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | XX | D3 | 00 | Q | Q | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 07/13/1980 | Active |