NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925004766337 | CIRCUIT BREAKER | 06/09/1974 | X | Pending Cancellation |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
2539700-1 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
FHL26040-5830 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
FHL26040 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
TERMINAL TYPE AND QUANTITY | 4 COMPRESSION |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
RESET METHOD | MANUAL |
POLE QUANTITY | 2 |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 18000.0 AC AND 10000.0 DC ALL LOCATIONS |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 3.000 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.171 INCHES NOMINAL |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE TWO |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.125 INCHES NOMINAL |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 ALL LOCATIONS |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC AND 250.0 DC ALL LOCATIONS |
SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.125 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.500 INCHES NOMINAL |
TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
ACTUATOR FUNCTION | TRIP-RESET |
FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | +325.0 TO 400.0 AC AND +325.0 TO 400.0 DC ALL LOCATIONS |
CIRCUIT PROTECTION TYPE | UNDERVOLTAGE ALL LOCATIONS |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC AND 40.0 AMPERES DC ALL LOCATIONS |
TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
SWITCH TERMINAL TYPE | WIRE LEAD |
BOSS HEIGHT | 0.155 INCHES NOMINAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CASE MATERIAL | PLASTIC |
FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
BODY HEIGHT | 3.000 INCHES NOMINAL |
BODY WIDTH | 4.468 INCHES NOMINAL |
BODY LENGTH | 6.000 INCHES NOMINAL |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 07/01/2005 | |||||||||||
ZC01 | 04/01/1991 | |||||||||||
ZP01 | 04/01/1997 | |||||||||||
ZW01 | 11/01/1998 | |||||||||||
ZN01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HD | 72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH BOXES/ELEC ENCLOSURES |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 69Z0 | 41 | 1 | AAA | 4.5 lbs | 0.1 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | JC | X | D3 | DO | 00 | Q | Q | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized - Pending decision | TX | 12/01/1974 | Pending Cancellation |