5925004797904

CIRCUIT BREAKER

Part No.: 13MC2-203-3-5,APL111R853-100,AM333HKMG6-3-5-250-400-15,260-0952-100,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925004797904 CIRCUIT BREAKER 02/11/1970 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
13MC2-203-3-5 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL111R853-100 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM333HKMG6-3-5-250-400-15 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
260-0952-100 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
THREAD PITCH DIAMETERS +0.1177 TO 0.1214 INCHES
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
SWITCH CURRENT RATING AND TYPE IN AMPS 2.5 AC AND 1.0 DC
ACTUATOR FUNCTION TRIP-RESET
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
ACTUATOR POSITION DESIGNATION AT EACH POLE
NOMINAL THREAD SIZE 0.138 INCHES
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.050 INCHES NOMINAL
THREAD QUANTITY PER INCH 32
BOSS HEIGHT 0.130 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.5 AMPERES AC ALL LOCATIONS
CASE MATERIAL PLASTIC
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE THREE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.660 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
SWITCH TERMINAL TYPE TAB, SOLDER LUG
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
POLE QUANTITY 3
RESET METHOD MANUAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.050 MINIMUM AT 200 PCT AND 8.800 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES MAXIMUM
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
BODY WIDTH 2.200 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY LENGTH 2.530 INCHES MAXIMUM
TEST DATA DOCUMENT 13499-260-0952 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
TERMINAL TYPE AND QUANTITY 6 THREADED STUD

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZG01 04/01/1991
YD01 08/01/2016

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P 69F0 3G 1 AAA
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 FA BG X D1 DO 99 E Q U

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 02/10/1980 Active