NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925004797908 | CIRCUIT BREAKER | 02/11/1970 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
APL1R571-200 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
260-4021-200 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
AM12HKMG6-5-250-4-60 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
BODY LENGTH | 2.530 INCHES MAXIMUM |
FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
RESET METHOD | MANUAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CASE MATERIAL | PLASTIC |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.900 INCHES MAXIMUM |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
ACTUATOR FUNCTION | TRIP-RESET |
NOMINAL THREAD SIZE | 0.138 INCHES |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
POLE QUANTITY | 1 |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
BOSS HEIGHT | 0.145 INCHES MINIMUM AND 0.160 INCHES MAXIMUM |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 SINGLE LOCATION |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC SINGLE LOCATION |
SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
THREAD QUANTITY PER INCH | 32 |
SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
SPECIAL HANDLING FEATURE | MAGNETIC |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.950 INCHES MINIMUM AND 1.970 INCHES MAXIMUM |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 200 PCT AND 20.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HUMIDITY RESISTANT AND SALT SPRAY PROOF AND DUSTPROOF AND SAND RESISTANT AND EXPLOSION PROOF AND VIBRATIONPROOF |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
BODY WIDTH | 0.755 INCHES MINIMUM AND 0.770 INCHES MAXIMUM |
BODY STYLE | SINGLE POLE TYPE |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
THREAD SERIES DESIGNATOR | UNC |
THREAD PITCH DIAMETERS | +0.1177 TO 0.1214 INCHES |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 11/01/2005 | |||||||||||
ZF01 | 02/01/1997 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | 69Z0 | 3G | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 99 | E | Q | U | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized - Replacement | TX | 04/01/1975 | Active |