CIRCUIT BREAKER

Part No.: 13208E9625,13208E9625,WC375/20-005,W-C-375/20,2263CMG4-30-120-240VAC60C9,2263CCURVE1S,2263C-30-240-1,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925004888030 CIRCUIT BREAKER 05/22/1970 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
13208E9625 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
13208E9625 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
WC375/20-005 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
W-C-375/20 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
2263CMG4-30-120-240VAC60C9 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
2263CCURVE1S ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
2263C-30-240-1 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT EACH POLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
POLE QUANTITY 2
CASE MATERIAL PLASTIC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 40.000 MINIMUM AT 200 PCT AND 100.500 MAXIMUM AT 200 PCT ALL LOCATIONS
THREAD QUANTITY PER INCH 32
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
NOMINAL THREAD SIZE 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
RESET METHOD MANUAL
FRAGILITY FACTOR MODERATELY RUGGED
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 135.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED CORROSION RESISTANT
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC ALL LOCATIONS
TEST DATA DOCUMENT 81348-W-C-375/20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TERMINAL TYPE AND QUANTITY 4 COMPRESSION
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
THREAD SERIES DESIGNATOR UNC
SPECIFICATION/STANDARD DATA 81348-W-C-375/20-005 GOVERNMENT SPECIFICATION

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
VJ01 12/01/2018
ZW01 11/01/2005
ZC01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
AJ 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69FZ ZZ X XXX
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
XX XX XX X XX XX 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/15/1974 Active