5925005019686

CIRCUIT BREAKER

Part No.: 93905PC470ATRIP,6205-3116035PC470ATRIP,ETN4870,574-6201-810906REVDPC41,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925005019686 CIRCUIT BREAKER 01/01/1963 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
93905PC470ATRIP ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
6205-3116035PC470ATRIP ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
ETN4870 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
574-6201-810906REVDPC41 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
SPECIAL FEATURES INCLUDES INSTANTANEOUS 330 TO 350 AMP MECHANICAL TIMER
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 500.0 AC ALL LOCATIONS
RESET METHOD MANUAL
ACTUATOR FUNCTION TRIP-RESET
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CASE MATERIAL PLASTIC
POLE QUANTITY 3
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE METHOD THERMAL ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED STUD
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 470.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 4000.0 AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
ACTUATOR POSITION DESIGNATION AT EACH POLE
TERMINAL TYPE AND QUANTITY 6 THREADED STUD

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZC01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69FZ ZZ X XXX
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
XX XX XX X XX XX 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/15/1974 Active