5925005682455

CIRCUIT BREAKER

Part No.: 7373-45,89-743662-22,122-250-101,AM12MG6-50-250VAC60C4,760181,7902754-13,W91X11-2-50,7373-45,APL-1-1-62-503,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925005682455 CIRCUIT BREAKER 01/01/1963 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
7373-45 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
89-743662-22 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
122-250-101 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AM12MG6-50-250VAC60C4 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
760181 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
7902754-13 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
W91X11-2-50 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
7373-45 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
APL-1-1-62-503 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
THREAD SERIES DESIGNATOR UNC
BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
SPECIAL HANDLING FEATURE MAGNETIC
BODY STYLE SINGLE POLE TYPE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CASE MATERIAL PLASTIC
UNPACKAGED UNIT WEIGHT 0.312 POUNDS NOMINAL
ACTUATOR POSITION DESIGNATION AT POLE ONE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.549 INCHES MINIMUM AND 2.673 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
NOMINAL THREAD SIZE 0.138 INCHES
ARC QUENCHING METHOD MAGNETIC BLOWOUT
POLE QUANTITY 1
ACTUATOR FUNCTION TRIP-RESET
TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND VIBRATION RESISTANT
FRAGILITY FACTOR MODERATELY RUGGED
THREAD QUANTITY PER INCH 32
RESET METHOD MANUAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
FREQUENCY IN HERTZ 50.0 OR 60.0 SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC SINGLE LOCATION
BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZC01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 04/01/1975 Active