NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925005704771 | CIRCUIT BREAKER | 12/01/1974 | X | Inactive |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
APL1-1R0-55629/2-128 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
MIL-C-55629/2 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
MIL-PRF-55629/2 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
M55629/2-128 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|---|---|---|---|---|---|---|---|---|
DLA | SMS | J | 1 | EA | 49.67 | 0 | 10/01/2022 |
Name | Value |
---|---|
THREAD SERIES DESIGNATOR | UNC |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
TEST DATA DOCUMENT | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
RESET METHOD | MANUAL |
THREAD QUANTITY PER INCH | 32 |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CASE MATERIAL | PLASTIC |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.800 INCHES MAXIMUM |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.130 MINIMUM AT 200 PCT AND 1.400 MAXIMUM AT 200 PCT SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC SINGLE LOCATION |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BOSS HEIGHT | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES DC SINGLE LOCATION |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
FRAGILITY FACTOR | MODERATELY RUGGED |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
POLE QUANTITY | 1 |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
NOMINAL THREAD SIZE | 0.138 INCHES |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
ACTUATOR FUNCTION | TRIP-RESET |
SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 2.0 DC |
SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
BODY STYLE | SINGLE POLE TYPE |
BODY LENGTH | 2.510 INCHES MAXIMUM |
THREAD PITCH DIAMETERS | +0.1177 TO 0.1214 INCHES |
SPECIFICATION/STANDARD DATA | 81349-MIL-C-55629/2 GOVERNMENT SPECIFICATION |
BODY WIDTH | 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
BGX1 | 1 | T | 05/01/2008 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH BOXES/ELEC ENCLOSURES |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 69F0 | B | 41 | 1 | AAA | 0.1 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | C | D3 | DO | 00 | Q | Q | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 12/01/1974 | Inactive |