NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925005831913 | CIRCUIT BREAKER | 01/01/1963 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
MP-714 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|---|---|---|---|---|---|---|---|---|
DLA | SMS | Y | 1 | EA | 32.65 | 0 | 10/01/2004 | DISCONTINUED W/O REPLACEMENT |
Name | Value |
---|---|
TEST DATA DOCUMENT | 76374-MP-714 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
NOMINAL THREAD SIZE | 0.469 INCHES |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC AND 20.0 AMPERES DC ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED BUSHING |
CASE MATERIAL | PLASTIC |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC AND 6000.0 DC ALL LOCATIONS |
ACTUATOR FUNCTION | TRIP-RESET |
UNPACKAGED UNIT WEIGHT | 0.330 POUNDS NOMINAL |
POLE QUANTITY | 3 |
TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
MANUAL ACTUATOR TYPE AND QUANTITY | 3 PUSH-PULL |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT |
RESET METHOD | MANUAL |
THREAD QUANTITY PER INCH | 32 |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 30.0 DC ALL LOCATIONS |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.450 INCHES MINIMUM AND 0.640 INCHES MAXIMUM |
TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
FRAGILITY FACTOR | MODERATELY RUGGED |
FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.813 INCHES MAXIMUM |
ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
BODY WIDTH | 2.407 INCHES MINIMUM AND 2.437 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
THREAD SERIES DESIGNATOR | UNS |
BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
BODY LENGTH | 2.235 INCHES MINIMUM AND 2.265 INCHES MAXIMUM |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
YA01 | 01/01/2017 | |||||||||||
ZC01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX | 72D | Z | 9 | A | H | Z | W | 063160 | Z | 35205 | SWITCH BOXES/ELEC ENCLOSURES |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 69F0 | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 00 | Q | Q | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 07/10/1970 | Active |