NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925005928571 | CIRCUIT BREAKER | 01/01/1963 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
2176SKMG4 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
150-0665 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
1033-21A | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
FRAGILITY FACTOR | MODERATELY RUGGED |
POLE QUANTITY | 2 |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM |
ACTUATOR FUNCTION | TRIP-RESET |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE AND 2 UNTHREADED HOLE |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
BOSS HEIGHT | 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.320 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM |
THREAD QUANTITY PER INCH | 32 |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
NOMINAL THREAD SIZE | 0.164 INCHES |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 125.0 DC ALL LOCATIONS |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 200.0 MILLIAMPERES DC ALL LOCATIONS |
CASE MATERIAL | PLASTIC |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC AND 5000.0 DC ALL LOCATIONS |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
RESET METHOD | MANUAL |
BODY LENGTH | 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM |
BODY HEIGHT | 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM |
BODY WIDTH | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
THREAD SERIES DESIGNATOR | UNC |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 12/01/2005 | |||||||||||
YA01 | 01/01/2002 | |||||||||||
ZU01 | 07/01/2005 | |||||||||||
ZH01 | 04/01/1991 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 69Z0 | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 00 | Q | Q | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized for Procurement | TX | 12/15/1974 | Active |