5925006203971

CIRCUIT BREAKER

Part No.: ALB5-30A,MIL-C-17588,ETN1064,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925006203971 CIRCUIT BREAKER 01/01/1961 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
ALB5-30A ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
MIL-C-17588 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
ETN1064 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
THREAD SERIES DESIGNATOR UNC
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 2.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 0.500 INCHES NOMINAL
BOSS HEIGHT 0.125 INCHES NOMINAL
RESET METHOD MANUAL
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 125.0 AC AND 125.0 DC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC AND 5000.0 DC ALL LOCATIONS
NOMINAL THREAD SIZE 0.216 INCHES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCKPROOF AND VIBRATIONPROOF
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC AND 30.0 AMPERES DC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 2.937 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.125 INCHES NOMINAL
POLE QUANTITY 3
CASE MATERIAL PLASTIC
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
THREAD QUANTITY PER INCH 24
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 10.000 MINIMUM AT 125 PCT AND 100.000 MAXIMUM AT 125 PCT ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT POLE TWO
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
ULTIMATE TRIP TIME PER POLE IN SECONDS 3600.000 NOMINAL ALL LOCATIONS
BODY HEIGHT 3.375 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 6 QUICK DISCONNECT, MALE
TEST DATA DOCUMENT 81349-MIL-C-17588 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
BODY LENGTH 4.125 INCHES NOMINAL
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
BODY WIDTH 3.344 INCHES NOMINAL

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZR01 07/01/1997
YA01 01/01/2002
ZH01 04/01/1991
ZC01 04/01/1991
ZW01 11/01/1998
ZU01 04/01/1991

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX 658 Z 9 A H Z M 061360 X 34430 COILS/YOKES FOCUS/DEFLECTION TV

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 07/30/1998 Active