5925006264343

CIRCUIT BREAKER

Part No.: HB2Z1-68,MILC39019-3,M39019-3-68,SM33-15-60-1,SM33-15-250VAC60C1,AP12-1-6-2-153,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925006264343 CIRCUIT BREAKER 02/02/1968 X Active

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
HB2Z1-68 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
MILC39019-3 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
M39019-3-68 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
SM33-15-60-1 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
SM33-15-250VAC60C1 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
AP12-1-6-2-153 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC

Technical Info

Name Value
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
THREAD SERIES DESIGNATOR UNEF
SPECIFICATION/STANDARD DATA 81349-MIL-C-39019/3 GOVERNMENT SPECIFICATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TEST DATA DOCUMENT 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
NOMINAL THREAD SIZE 0.375 INCHES
FRAGILITY FACTOR MODERATELY RUGGED
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
RESET METHOD MANUAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
POLE QUANTITY 2
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
THREAD QUANTITY PER INCH 32
ACTUATOR FUNCTION TRIP-RESET
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
ARC QUENCHING METHOD MAGNETIC BLOWOUT
SPECIAL HANDLING FEATURE MAGNETIC
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT EACH POLE
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS 3.000 MINIMUM AND 60.000 MAXIMUM ALL LOCATIONS
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
BUSHING LENGTH 0.380 INCHES MAXIMUM
THREAD PITCH DIAMETERS +0.3503 TO 0.3537 INCHES
BODY LENGTH 1.562 INCHES MAXIMUM
BODY WIDTH 1.281 INCHES MAXIMUM

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
ZW01 11/01/1998
ZC01 04/01/1991
ZR01 07/01/1997

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
TX 72D Z 9 A H Z W 063160 Z 35205 SWITCH BOXES/ELEC ENCLOSURES

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69FZ ZZ X XXX
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
XX XX XX X XX XX 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized - Replacement TX 12/21/1976 Active