NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5925006860552 | CIRCUIT BREAKER | 01/01/1963 | X | Pending Cancellation |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
9073376 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
AM333MG6-3-115-15-400 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
9073376 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
70-762-3 0AMP | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
9169336 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|
Name | Value |
---|---|
PRECIOUS MATERIAL AND LOCATION | TERMINAL AND CONTACT SURFACES SILVER |
NOMINAL THREAD SIZE | 0.138 INCHES |
ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.875 INCHES MINIMUM AND 1.999 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
SPECIAL HANDLING FEATURE | MAGNETIC |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
ULTIMATE TRIP TIME PER POLE IN SECONDS | 25.000 NOMINAL ALL LOCATIONS |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.677 INCHES MAXIMUM |
FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
THREAD QUANTITY PER INCH | 32 |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES AC ALL LOCATIONS |
POLE QUANTITY | 3 |
ACTUATOR POSITION DESIGNATION | AT EACH POLE |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
ACTUATOR FUNCTION | TRIP-RESET |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS |
CASE MATERIAL | PLASTIC |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
FRAGILITY FACTOR | MODERATELY RUGGED |
BOSS HEIGHT | 0.110 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 200 PCT AND 8.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
RESET METHOD | MANUAL |
UNPACKAGED UNIT WEIGHT | 0.875 POUNDS NOMINAL |
BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
BODY WIDTH | 2.235 INCHES MINIMUM AND 2.265 INCHES MAXIMUM |
BODY LENGTH | 2.531 INCHES MAXIMUM |
THREAD SERIES DESIGNATOR | UNC |
TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
PRECIOUS MATERIAL | SILVER |
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
FIIG | INC | Description | Detail |
---|---|---|---|
00136 | 00136 | CIRCUIT BREAKER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 09/01/2008 | |||||||||||
ZH01 | 04/01/1991 | |||||||||||
ZU01 | 08/01/1995 | |||||||||||
ZR01 | 07/01/1997 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX | 723 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS/YOKES FOCUS/DEFLECTION TV |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
Status Code | Originator | Date | Status |
---|---|---|---|
Authorized - Replacement | TX | 06/20/1974 | Pending Cancellation |