5925006910019

CIRCUIT BREAKER

Part No.: DMS CASE 83-059B,76-103-4,860028-27,860028-27,

NSN Summary
NSN Description Assign Criticality Status Codification Country
5925006910019 CIRCUIT BREAKER 01/01/1961 X Pending Cancellation

Open Solicitations

Issued Closing Solicitation Clin Cage ECV Status

Request A Demo

Request a Demo to see all details.

Request Demo

Manufacturers

Part Number Company Cage P/N added P/N deleted RNVC RNCC RNAAC RNFC SADC DAC Item Status
DMS CASE 83-059B ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
76-103-4 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
860028-27 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########
860028-27 ######### ######### ######### ######### ######### ######### ######### ######### ######### ######### #########

Request A Demo

Request a Demo to see all details.

Procurement History

Company Cage Award Date Qty Unit Price Total Price Contract Delivery

Request A Demo

Request a Demo to see all details.

Request Demo

Management Data

MOE SOS AAC Unit Pack UOM Unit Price SLC Date ELA FCS MCC
Navy SMS Y 1 EA 677.77 0 10/01/2022
DLA SMS Y 1 EA 677.77 0 10/01/2022

Technical Info

Name Value
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
THREAD SERIES DESIGNATOR UNC
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 18.000 MINIMUM AT 200 PCT AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
NOMINAL THREAD SIZE 0.164 INCHES
ULTIMATE TRIP TIME PER POLE IN SECONDS 340.000 MAXIMUM ALL LOCATIONS
FRAGILITY FACTOR MODERATELY RUGGED
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
ARC QUENCHING METHOD AIR
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC ALL LOCATIONS
ACTUATOR POSITION DESIGNATION AT EACH POLE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM
THREAD QUANTITY PER INCH 32
ACTUATOR FUNCTION TRIP-RESET
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3500.0 AC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
CASE MATERIAL PLASTIC
RESET METHOD MANUAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 208.0 AC ALL LOCATIONS
POLE QUANTITY 3
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY 6 SCREW
BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY WIDTH 2.263 INCHES MINIMUM AND 2.283 INCHES MAXIMUM
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.


FIIG Inc Info

FIIG INC Description Detail
00136 00136 CIRCUIT BREAKER

MOE Data

Country MOE AMC AMSC NIMSC Eff Date IMC IMCA DSOR Collaborator Receiver AAC FMOE
WG01 11/01/2017

Freight Data

Integrity Originating HMC WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
XX 72D Z 9 A H Z W 063160 Z 35205 SWITCH BOXES/ELEC ENCLOSURES

Packaging Data

Source PICA / SICA Packaging Category Storage Preservation Clean/Dry INT Qty Unit Weight Unit Size Unit Pack Cube Item Weight Item Dims
P P 69F0 B 41 1 AAA 0.9 lbs 0.022 cu ft
Preservation Material Wrapping Material Cushioning / Dunnage Cushioning Thickness Unit Container Intermediate Container UCL Special Marking Level A Packing Level B Packing Minimal Packing Optional Procedure
00 00 NA C D3 DO 00 Q Q O

Item Standardization

Status Code Originator Date Status
Authorized for Procurement TX 12/21/1969 Pending Cancellation