NSN | Description | Assign | Criticality | Status | Codification Country |
---|---|---|---|---|---|
5950000621267 | TRANSFORMER,POWER | 01/01/1963 | X | Active |
Issued | Closing | Solicitation | Clin | Cage | ECV | Status |
---|
Part Number | Company | Cage | P/N added | P/N deleted | RNVC | RNCC | RNAAC | RNFC | SADC | DAC | Item Status |
---|---|---|---|---|---|---|---|---|---|---|---|
570133 | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### | ######### |
Company | Cage | Award Date | Qty | Unit Price | Total Price | Contract | Delivery |
---|
MOE | SOS | AAC | Unit Pack | UOM | Unit Price | SLC | Date ELA | FCS | MCC |
---|---|---|---|---|---|---|---|---|---|
DLA | SMS | J | 1 | EA | 215.09 | 0 | 10/01/2022 |
A PHP Error was encounteredSeverity: Notice Message: Undefined index: frase_code_statement Filename: open_search/nsn_details.php Line Number: 248 Backtrace:
File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
File: /var/www/www.fbobiz.com/public_html/catalog/index.php A PHP Error was encounteredSeverity: Notice Message: Undefined index: frase_code_statement Filename: open_search/nsn_details.php Line Number: 256 Backtrace:
File: /var/www/www.fbobiz.com/public_html/catalog/application/views/open_search/nsn_details.php
File: /var/www/www.fbobiz.com/public_html/catalog/application/controllers/Opensearch.php
File: /var/www/www.fbobiz.com/public_html/catalog/index.php |
Name | Value |
---|---|
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
INCLOSURE TYPE | HERMETICALLY SEALED |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BODY WIDTH | 2.297 INCHES NOMINAL |
SPECIAL FEATURES | CENTER TAP INTERNALLY CONNECTED ONE SIDE OF 6.3 WINDING |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
BODY LENGTH | 2.812 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
OVERALL HEIGHT | 3.219 INCHES NOMINAL |
WINDING OPERATING VOLTAGE | 660.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 8 TURRET |
WINDING OPERATING CURRENT | 5.2 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.
FIIG | INC | Description | Detail |
---|---|---|---|
32496 | 32496 | TRANSFORMER,POWER |
Country | MOE | AMC | AMSC | NIMSC | Eff Date | IMC | IMCA | DSOR | Collaborator | Receiver | AAC | FMOE |
---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | 5 | L | 04/01/2007 |
Integrity | Originating | HMC | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XX | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 69F0 | A | 10 | 1 | AAA | 3 lbs | 0.072 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | UCL | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | ZZ | C | D3 | DO | 00 | Q | Q | U | O |
Status Code | Originator | Date | Status |
---|---|---|---|
Authorize in specific FSC | TX | 07/17/1967 | Active |